Technical Services Standards

The following Technical Services Standard Details have been provided to assist in the preparation of documentation for Civil Engineering works within the City of Onkaparinga.

  • It is the responsibility of the individual to ensure that they are using the current version of these drawings. The City of Onkaparinga accepts no liability for issues arising from the use of superseded drawings.
  • These drawings may not suit all applications. Any proposed alterations to these drawings should be referred to the City of Onkaparinga for approval.
  • Any inconsistencies or omissions in these drawings should be brought to the attention of the City of Onkaparinga for clarification or amendment.
  • Electronic versions of these drawings are available for viewing or download below in PDF format.
  • Printed copies of these drawings are uncontrolled.
  • For further information contact the City of Onkaparinga at mail@onkaparinga.sa.gov.au or phone (08) 8384 0666.

To download a PDF version for viewing or printing click on the relevant link below:

Stormwater management design guide(PDF, 661KB)

Technical Service Standard Details - full details(PDF, 1MB)

Typical kerbing profiles (100 series)

DWG# Drawing title Rev Date
SD‑100 100 UPRIGHT KERB & GUTTER — INFALL TYPE (100 K&G)(PDF, 68KB) B AUG 12
SD‑101 150 UPRIGHT KERB & GUTTER — INFALL TYPE (150 K&G)(PDF, 69KB) B AUG 12
SD‑102 100 UPRIGHT KERB & TRAY — OUTFALL TYPE (100 K&T)(PDF, 69KB) B AUG 12
SD‑103 150 UPRIGHT KERB & TRAY — OUTFALL TYPE (150 K&T)(PDF, 69KB) B AUG 12
SD‑104 SPOON DRAIN - RESIDENTIAL & INDUSTRIAL (SD)(PDF, 67KB) B AUG 12
SD‑105 DRIVEWAY INVERT — INFALL TYPE — RESIDENTIAL & INDUSTRIAL (INV)(PDF, 106KB) C AUG 12
SD‑106 DRIVEWAY INVERT — OUTFALL TYPE — RESIDENTIAL & INDUSTRIAL (INV)(PDF, 106KB) C AUG 12
SD‑107 100 BARRIER KERB — (100 K)(PDF, 66KB) B AUG 12
SD‑108 150 BARRIER KERB — (150 K)(PDF, 67KB) B AUG 12
SD‑109 EDGE BEAM — (EB)(PDF, 66KB) B AUG 12
SD‑110 KEYED-IN KERB — FOR MEDIANS (MED) OR ROUNDABOUTS (RAB)(PDF, 67KB) C AUG 12
SD‑111 SIT-ON KERB — (SOK)(PDF, 66KB) B AUG 12
SD‑112 SEMI MOUNTABLE KERB & GUTTER — INFALL TYPE (SK&G)(PDF, 69KB) B AUG 12
SD‑113 SEMI MOUNTABLE KERB & TRAY — OUTFALL TYPE (SK&T)(PDF, 69KB) B AUG 12
SD‑114 SEMI MOUNTABLE KERB — (SK)(PDF, 67KB) B AUG 12
SD‑115 LOW PROFILE ROUNDABOUT KERB — (RAB)(PDF, 126KB) D FEB 18
SD‑116 900mm SPOON DRAIN - RESIDENTIAL & INDUSTRIAL (SD)(PDF, 122KB) A JUN 13
SD‑117 1200mm SPOON DRAIN - RESIDENTIAL & INDUSTRIAL (SD)(PDF, 123KB) A JUN 13

 

Typical drainage details (200 series)

DWG# Drawing title Rev Date
SD‑200 JUNCTION BOX (TYPE 1) — FOR PIPE SIZES ≤ ∅1050mm(PDF, 181KB) C FEB 18
SD‑201 JUNCTION BOX (TYPE 2) — FOR PIPE SIZES > ∅1050mm(PDF, 189KB) D FEB 18
SD‑202 GRATED INLET PIT (TYPE 1) — FOR PIPE SIZES ≤ ∅450mm(PDF, 177KB) C FEB 18
SD‑203 GRATED INLET PIT (TYPE 2) — FOR PIPE SIZES ≤ ∅1050mm(PDF, 180KB) C FEB 18
SD‑204 SADDLE PIT — FOR SMALL TO LARGE PIPE CONNECTION — WHERE LARGE PIPE SIZE ≥ ∅1050mm(PDF, 179KB) C FEB 18
SD‑205 FIELD GULLY — WITH 600mm CONCRETE APRON(PDF, 176KB) C FEB 18
SD‑206 DOUBLE SIDE ENTRY PIT (TYPE 1) — LINTEL TYPE — WITHOUT DEFLECTORS(PDF, 180KB) D FEB 18
SD‑207 DOUBLE SIDE ENTRY PIT (TYPE 2) — LINTEL TYPE — WITH DEFLECTORS(PDF, 184KB) D FEB 18
SD‑208 DOUBLE SIDE ENTRY PIT (TYPE 3) — COVER & FRAME TYPE — WITHOUT DEFLECTORS(PDF, 185KB) D FEB 18
SD‑209 DOUBLE SIDE ENTRY PIT (TYPE 4) — COVER & FRAME TYPE — WITH DEFLECTORS(PDF, 187KB) D FEB 18
SD‑210 PIT BENCHING (STREAMLINING) — TO BE USED FOR ALL DRAINAGE PITS(PDF, 145KB) C FEB 18
SD‑211 ‘CONFINED SPACE' WARNING SIGN — FOR ALL NEW DRAINAGE PITS(PDF, 142KB) B AUG 12
SD‑212 BANDAGE JOINT — FOR CONCRETE PIPES(PDF, 170KB) C FEB 18
SD‑213 DRAINAGE OUTLET TO KERB(PDF, 184KB) C FEB 18
SD‑214 DRAINAGE CROSSOVER (TYPE 1) — ALUMINIUM 'TOP HAT' SECTION(PDF, 135KB) B AUG 12
SD‑215 DRAINAGE CROSSOVER (TYPE 2) — STEEL 'BOX DRAIN'(PDF, 137KB) B AUG 12
SD‑216 STEP IRON DETAILS — FOR DRAINAGE PITS > 1.2m DEEP(PDF, 291KB) A AUG 12
SD‑220 ALLOTMENT CONNECTION (TYPE 1) TO REAR OF ALLOTMENT DRAIN — CONCRETE INSPECTION POINT COVER & SURROUND(PDF, 141KB) D FEB 18
SD‑221 ALLOTMENT CONNECTION (TYPE 2) TO REAR OF ALLOTMENT DRAIN — CONCRETE ALLOTMENT COLLECTION SLAB & PVC GRATE(PDF, 155KB) D FEB 18
SD‑222 ALLOTMENT CONNECTION (TYPE 3) TO FRONT OF ALLOTMENT DRAIN — CONCRETE INSPECTION POINT COVER & SURROUND(PDF, 141KB) D FEB 18
SD‑223 ALLOTMENT CONNECTION TO DRAIN — TO RCP OR FRCP ALLOTMENT DRAIN – FOR FRONT OR REAR OF ALLOTMENT DRAIN CONNECTIONS(PDF, 141KB) B AUG 12
SD‑230 SWALE INSTALLATION (TYPE 1) — 900mm ROCK LINED SWALE(PDF, 76KB) B AUG 12
SD‑231 SWALE INSTALLATION (TYPE 2) — AT DRIVEWAY CROSSOVERS — CEMENT TREATED(PDF, 131KB) C FEB 18

 

Typical path details (300 series)

DWG# Drawing title Rev Date
SD‑300 BLOCK PAVED FOOTPATH — (RESIDENTIAL)(PDF, 143KB) E FEB 18
SD‑301 BLOCK PAVED FOOTPATH — (INDUSTRIAL)(PDF, 149KB) E FEB 18
SD‑302 CONCRETE FOOTPATH — (RESIDENTIAL)(PDF, 213KB) E FEB 18
SD‑303 CONCRETE FOOTPATH — (INDUSTRIAL)(PDF, 218KB) E FEB 18
SD‑304 FOOTPATH & RETAINING WALL — RETAINING WALL ADJACENT FOOTPATH(PDF, 187KB) B AUG 12
SD‑305 ASPHALT FOOTPATH — (RESIDENTIAL)(PDF, 142KB) B FEB 18
SD‑306 ASPHALT FOOTPATH — (INDUSTRIAL)(PDF, 146KB) B FEB 18
SD‑307 EXPOSED AGGREGATE FOOTPATH — (RESIDENTIAL)(PDF, 216KB) B FEB 18
SD‑308 EXPOSED AGGREGATE FOOTPATH — (INDUSTRIAL)(PDF, 222KB) B FEB 18
SD‑309 PERMEABLE PAVED FOOTPATH - (RESIDENTIAL)(PDF, 143KB) A FEB 18
SD‑310 CONCRETE SHARED PATH(PDF, 213KB) D FEB 18
SD‑311 BLOCK PAVED SHARED PATH(PDF, 141KB) D FEB 18
SD‑312 SPRAY SEAL SHARED PATH (TYPE 1) — WITHOUT GEOGRID(PDF, 136KB) D FEB 18
SD‑313 SPRAY SEAL SHARED PATH (TYPE 2) — WITH 'TENSAR SS30' GEOGRID(PDF, 137KB) D FEB 18
SD‑314 ASPHALT SHARED PATH (TYPE 1) — WITHOUT GEOGRID(PDF, 136KB) D FEB 18
SD‑315 ASPHALT SHARED PATH (TYPE 2) — WITH 'TENSAR SS30' GEOGRID(PDF, 138KB) D FEB 18
SD‑316 CEMENT TREATED RUBBLE SHARED PATH(PDF, 142KB) D FEB 18
SD‑317 LIMESTONE RUBBLE SHARED PATH(PDF, 221KB) B AUG 12
SD‑320 KERB RAMP (TYPE 1) - FOR KERB RAMP WITH WINGS(PDF, 187KB) D FEB 18
SD‑322 KERB RAMP (TYPE 2) - FOR KERB RAMP WITH PLINTHS(PDF, 183KB) A FEB 18
SD‑325 FOOTPATH HOLDING RAIL INSTALLATION — AT KERB RAMP FOR PEDESTRIANS(PDF, 139KB) C FEB 18
SD‑326 SHARED PATH HOLDING RAIL INSTALLATION — AT KERB RAMP FOR PEDESTRIANS & CYCLISTS(PDF, 138KB) C FEB 18
SD‑327 PEDESTRIAN REFUGE(PDF, 180KB) C FEB 18
SD‑330 LOCALISED FOOTPATH WIDENING — TO ALLOW FOR BIN PLACEMENT(PDF, 131KB) D FEB 18
SD‑331 CONCRETE INFILL FOR SERVICE COVERS — FOR BLOCK PAVING(PDF, 76KB) B AUG 12
SD‑332 EDGE FOOTING INSTALLATION — INTERFACE BETWEEN PAVING & LANDSCAPED AREAS(PDF, 143KB) D FEB 18
SD‑340 CONCRETE FOOTPATH REPAIR - (RESIDENTIAL)(PDF, 230KB) A FEB 18

 

Typical installation details (400 series)

DWG# Drawing title Rev Date
SD‑400 KERB INSTALLATION (TYPE 1) — IN NEW PAVEMENT — WITH FUTURE VERGE TREATMENT(PDF, 135KB) D FEB 18
SD‑401 KERB INSTALLATION (TYPE 2) — IN NEW PAVEMENT — WITH FOOTPATH BEHIND KERB(PDF, 134KB) D FEB 18
SD‑402 KERB INSTALLATION (TYPE 3) — IN EXISTING PAVEMENT(PDF, 174KB) D FEB 18
SD‑403 KERB INSTALLATION (TYPE 4) — IN EXISTING PAVEMENT WITH 'CLSM' INFILL(PDF, 174KB) D FEB 18
SD‑404 KERB INSTALLATION (TYPE 5) — HOTMIX KERBING FOR TREE IN CLOSE PROXIMITY — IN EXISTING PAVEMENT(PDF, 207KB) B FEB 18
SD‑405 SIT-ON KERB INSTALLATION (TYPE 1) — IN NEW PAVEMENT(PDF, 137KB) C FEB 18
SD‑406 SIT-ON KERB INSTALLATION (TYPE 2) — IN EXISTING PAVEMENT(PDF, 139KB) C FEB 18
SD‑407 KEYED-IN KERB INSTALLATION (TYPE 1) – IN NEW PAVEMENT(PDF, 137KB) C FEB 18
SD‑408 KEYED-IN KERB INSTALLATION (TYPE 2) — IN EXISTING PAVEMENT(PDF, 139KB) C FEB 18
SD‑410 300mm CONCRETE FILLET AT KERB RADIUS' — FOR USE WHERE SPOON DRAIN OR EDGE STRIP IS USED(PDF, 137KB) C FEB 18
SD‑411 CONCRETE APRON INSTALLATION — TO DIRECT STORMWATER FLOWS AT INTERSECTION(PDF, 68KB) B AUG 12
SD‑420 DRIVEWAY INVERT & CROSSOVER INSTALLATION (RESIDENTIAL) DRIVEWAY INVERT FOR 150 UPRIGHT KERB PROFILE(PDF, 225KB) D FEB 18
SD‑421 DRIVEWAY INVERT & CROSSOVER INSTALLATION (INDUSTRIAL) DRIVEWAY INVERT FOR 150 UPRIGHT KERB PROFILE(PDF, 226KB) D FEB 18
SD‑422 DRIVEWAY INVERT (RESIDENTIAL & INDUSTRIAL) DRIVEWAY INVERT FOR 150 UPRIGHT KERB PROFILE(PDF, 169KB) D FEB 18
SD‑423 DRIVEWAY INVERT INSTALLATION (RESIDENTIAL & INDUSTRIAL) REPLACEMENT OF EXISTING KERBING(PDF, 218KB) B FEB 18
SD‑430 PAVEMENT REINSTATEMENT FOR TRENCHES & REPAIRS (TYPE 1) FOR LOCAL ROADS(PDF, 140KB) E FEB 18
SD‑431 PAVEMENT REINSTATEMENT FOR TRENCHES & REPAIRS (TYPE 2) FOR COLLECTOR & DISTRIBUTOR ROADS(PDF, 143KB) E FEB 18
SD‑432 DRAINAGE TRENCH BACKFILLING — BELOW SUB-BASE LEVEL FOR PIPE SIZES ≤ ∅1500mm(PDF, 183KB) D AUG 12
SD‑433 SERVICE TRENCH BACKFILLING — BELOW SUB-BASE LEVEL FOR CONDUITS OR SERVICES(PDF, 110KB) D AUG 12
SD‑440 MEDIAN ISLAND KERB INSTALLATION (TYPE 1) CONTROLLED LOW STRENGTH MATERIAL (CLSM) INFILL(PDF, 76KB) B AUG 12
SD‑441 MEDIAN ISLAND KERB INSTALLATION (TYPE 2) — PATTERN FINISH CONCRETE INFILL(PDF, 71KB) B AUG 12
SD‑442 SPLITTER ISLAND INSTALLATION (TYPE 1) — BACK TO BACK SIT-ON KERB(PDF, 68KB) B AUG 12
SD‑445 MEDIAN ISLAND KERB INSTALLATION (TYPE 3) CONTROLLED LOW STRENGTH MATERIAL (CLSM) INFILL(PDF, 77KB) B AUG 12
SD‑446 MEDIAN ISLAND KERB INSTALLATION (TYPE 4) — PATTERN FINISH CONCRETE INFILL(PDF, 71KB) B AUG 12
SD‑447 SPLITTER ISLAND INSTALLATION (TYPE 2) — BACK TO BACK KEYED-IN KERB(PDF, 68KB) B AUG 12
SD‑450 ROUNDABOUT INSTALLATION (TYPE 1) WITH MOUNTABLE ISLAND AND LANDSCAPED CENTER ISLAND(PDF, 153KB) C FEB 18
SD‑451 ROUNDABOUT INSTALLATION (TYPE 2) — PATTERN FINISH CONCRETE INFILL(PDF, 144KB) C FEB 18
SD‑460 SPOON DRAIN INSTALLATION (TYPE 1) — IN NEW PAVEMENT(PDF, 71KB) A AUG 12
SD‑461 SPOON DRAIN INSTALLATION (TYPE 2) — IN EXISTING PAVEMENT(PDF, 172KB) B FEB 18
SD‑462 SPOON DRAIN INSTALLATION (TYPE 3) — IN EXISTING PAVEMENT WITH 'CLSM' INFILL(PDF, 171KB) B FEB 18

 

Typical landscaping details (600 series)

DWG# Drawing title Rev Date
SD‑600 PLANTING – SHRUBS(PDF, 136KB) A FEB 18
SD‑601 PLANTING – ADVANCED TREES(PDF, 218KB) A FEB 18
SD‑610 SPADE EDGE – (SE)(PDF, 148KB) A FEB 18
SD‑611 HARD EDGE – HARDWOOD OR WOOD PLASTIC COMPOSITE (HE)(PDF, 149KB) A FEB 18
SD‑620 EDGE BEAM – INTERFACE BETWEEN PAVEMENT & LANDSCAPING(PDF, 134KB) A FEB 18
SD‑630 BOLLARD INSTALLATION – WOOD PLASTIC COMPOSITE(PDF, 129KB) A FEB 18